堿性圓柱蓄電池自放電擱置時間的探討
作者:宋清山 鄒英 上傳時間:2005/3/19 16:20:49
摘要:自放電是堿性蓄電池的一項重要性指標,而科學、簡便地檢測方法是保證該指標正常的重要途徑。傳統的做法是將電池的電量充足,擱置28天后,測其實際容量,計算電池的自放量,這種方法比較接近實際情況,但在實際生產中嚴重影響了生產的進度。本文分析了堿性蓄電池自放電與擱置時間的關系,采用同一組樣本,擱置7天、14天、28天后,檢測其自放電量并進行對比。試驗結果表明:堿性蓄電池的自放電量大部分集中在充電后的前7天,因此,在生產中必須詳細探索擱置時間與自放電量的對應關系,探索擱置28天與擱置7天、14天自放電的不同。制定擱置7天、14天的自放電標準,節約生產時間,縮短生產周期,加快資金周轉。
敘詞:堿性蓄電池 自放電 擱置時間
Abstract:Self-discharge were a important characteristies guideline of Cd/Ni storage battery.Guideline of self-discharge require scientific and handy method come true.Conventional method were de regle charge at storage battery,place 28 day at normalk temperature,measuring actual electric quantity,and calculate self-discharge,this method be close to physical truth,but serious influence production plan.Relation of self-discharge and place time were analyzed in this paper,self-discharge of place 7 day,14 day and 28 day proceed contrase.The results of expreiment indicated that self-discharge collect at place ahead 7 day,so must detail explore relation of self-discharge and place time,contrast of self-discharge place 28 day,place 14 day.Enactment of rule place 7 day and place 14 day,cut down production time,horten production cycle,accelerate turnover of capital.
Keyword:alkaline storage battery self-discharge place time
說明:本站會員正確輸入用戶名和密碼進行登錄系統后才能查看文章詳細內容和參與評論。
--本文摘自《電源世界》,已被閱讀11291次
免責聲明:本文僅代表作者個人觀點,與電源在線網無關。其原創性以及文中陳述文字和內容未經本站證實,對本文以及其中全部或者部分內容、文字的真實性、完整性、及時性本站不作任何保證或承諾,請讀者僅作參考,并請自行核實相關內容。