直流電壓前饋控制數字逆變電源設計與實現
作者:李永富 上傳時間:2012/5/16 10:06:52
摘要:針對雙環控制逆變電源在直流側電壓擾動時輸出電壓波形畸變、幅值變化的問題,設計了一種直流電壓前饋控制逆變器,分析了利用輸入電壓解耦方法消除擾動的前饋控制原理。采用HPWM(Hybrid Pulse Width Modulation)調制方式,設計實現了基于DSP的全數字式低諧波逆變電源方案。仿真和實驗結果表明,該逆變電源能輸出較理想的正弦波形電壓,逆變電源在輸入直流電壓擾動下,有很好的正弦輸出波形和穩定的幅值,4個開關管均能實現零電壓開通和關斷,系統具有良好的動、靜態特性。
敘詞:逆變電源 前饋控制 數字控制 軟開關
Abstract:A DC feedforward control inverter is designed following the analysis of problems of wave distortion and amplitude change of output voltage resulting from voltage turbulence on the DC side of double-loop control inversion power supply. Feedforward control principle is analysed to erase turbulence applying input voltage decoupling. Whole-digital low harmonic inversion power supply scheme based on DSP is realized by adopting the HPWM modulation. Simulation and experimental results show that the inversion power supply can put out ideal sine wave voltage, can realize excellent sine output wave and stable amplitude value under the DC turbulence, and four switches can all realize zero-voltage switch on-and-off, which demonstrate that the system enjoys excellent dynamic and static features.
Keyword:Inversion power supply, Feedforward control, Digital control, Soft switch
說明:本站會員正確輸入用戶名和密碼進行登錄系統后才能查看文章詳細內容和參與評論。
--本文摘自《電源世界》,已被閱讀130004次
免責聲明:本文僅代表作者個人觀點,與電源在線網無關。其原創性以及文中陳述文字和內容未經本站證實,對本文以及其中全部或者部分內容、文字的真實性、完整性、及時性本站不作任何保證或承諾,請讀者僅作參考,并請自行核實相關內容。