蓄電池在線內阻在直流電源系統中的監測技術及運用
作者:關大凱 上傳時間:2010/4/7 15:13:56
摘要:通過分析直流電源系統中VRLA蓄電池運行狀況和電池失效的常見現象,研究了蓄電池在線監測管理系統應解決的關鍵問題,主要包括:①監測管理系統的合理結構;②電池組及電池單體的電壓、電流巡檢與數據分析;③電池單體的內阻測量;④電池運行事件記錄;⑤遠程管理。文中結合BM-6500電池管理系統在直流電源系統的應用進行了相關論述,本系統提高了直流電源運行的可靠性。
敘詞:蓄電池 監測 內阻測量 在線維護
Abstract:Basing on analyze to the run state and the phenomenon of runaway of VRLA battery used in DC power systems, the key technologies of the on-line battery internal resistance monitoring system have been studied. They are the reasonable structure; monitoring batteries and analyzing the data; internal resistance testing and alarming; running accident recording; remote management. Combining with the experience from developing the BM-6500 series of battery management systems, the related problems have been discussed in this paper. this system can promote the reliability of DC power sources which service in DCpower systems.
Keyword:VRLAB, Monitor, Internal resistance measurement, On-line maintenance
說明:本站會員正確輸入用戶名和密碼進行登錄系統后才能查看文章詳細內容和參與評論。
--本文摘自《電源世界》,已被閱讀2594次
免責聲明:本文僅代表作者個人觀點,與電源在線網無關。其原創性以及文中陳述文字和內容未經本站證實,對本文以及其中全部或者部分內容、文字的真實性、完整性、及時性本站不作任何保證或承諾,請讀者僅作參考,并請自行核實相關內容。